Lightning Flashover Rates of Overhead Distribution Lines Applying EMTP and IEEE Std.1410
Main Article Content
Abstract
This paper calculates the lightning flashover rates of 22 kV overhead distribution line. In order to calculate the backflashover rate (BFOR), the performance of line which related to the insulator backflashover has been modeled and analyzed using Electromagnetic Transient Program (EMTP). The flashover models, volt time curve (VT), disruptive effect model (DE) and leader progression model (LPM) have been compared. The shielding failure flashover rate (SFFOR) and induced voltage flashover rate (IVFOR) have been calculated follow equations given in IEEE std 1410-2010. Finally the total numbers of flashovers of line have been determined. The lightning flashovers rates of BFOR, SFFOR and IVFOR have also been compared with the data taken from the line outages recorder. From the system being studied shown that, the total numbers of flashovers from simulation and calculation is closed to the data from the line outage recorder.
Article Details
This journal provides immediate open access to its content on the principle that making research freely available to the public supports a greater global exchange of knowledge.
- Creative Commons Copyright License
The journal allows readers to download and share all published articles as long as they properly cite such articles; however, they cannot change them or use them commercially. This is classified as CC BY-NC-ND for the creative commons license.
- Retention of Copyright and Publishing Rights
The journal allows the authors of the published articles to hold copyrights and publishing rights without restrictions.
References
[2] R. P. Souza, I. J. S. Lopes and J. O. S. Paulino, “Influence of Electrogeometric Model and Statistical Current Distribution in Distribution Lines Indirect Lightning Performance Estimation Considering
the Ground Resistivity,” IEEE/PES T&D Latin America, November 8-10, 2010, Sao Paulo.
[3] J. O. S. Paulino, C. F. Barbosa, I. J. S. Lopes and W. d. C. Boaventura, “An Approximate Formula for the Peak Value of Lightning-Induced Voltages in Overhead Lines,” IEEE Transaction on Power Delivery, Vol. 25, No. 2, April, 2010.
[4] M. Darveniza, “A Practical Extension of Rusck’s Formula for Maximum Lightning-Induced Voltages That Accounts for Ground Resistivity,” IEEE Transaction on Power Delivery, Vol. 22, No. 1, January, 2007.
[5] A. Borghetti, C. A. Nucci and M. Paolone, “An Improved Procedure for the Assessment of Overhead Line Indirect Lightning Performance and Its Comparison with the IEEE Std. 1410 Method,” IEEE Transaction on Power Delivery, Vol. 22, No. 1, January, 2007.
[6] IEEE Std. 1410-2010, IEEE Guide for Improving the Lightning Performance of Electric Power Overhead Distribution Lines.
[7] PEA report document, “Report of Line Outages : PEA’s CM4 year 2008-2009”.
[8] H. K. HØidalen, L´aszl´o Prikler, ATPDraw version 5.7 for Windows 9x/NT/2000/XP/Vista/7, 2011.
[9] H.W. Dommel, “Electromagnetic Transients Program. Reference Manual (EMTP Theory Book),” Bonneville Power Administration, Portland, 1986.
[10] T.Mozumi,N. Nagaoka, A Ametani and S. Sekioka, “An Empirical Formula for the Surge Impedance of a Grounding Conductor along a Concrete Pole in Distribution Line,” International Conference on Power Systems Transients (IPST2001), June 24-28, 2001, Rio de Janeiro, Brazil,.
[11] IEEE Modeling and Analysis of System Transients Working Group, “Modeling Guidelines for Fast Front Transients,” IEEE Transactions on Power Delivery, Vol. 11, No. 1, January, 1996, pp. 493-506.
[12] IEEE Modeling and Analysis of System Transients Working Group, “Modeling Guidelines for Fast Front Transients,” IEEE Transactions on Power Delivery, Vol. 11, No. 1, January, 1996, pp. 493-506.
[13] Supatra Bhumiwat, “The First Year of Lightning Location Data in Thailand”, The Eight Asian Conference on Electrical Discharge, Bangkok, Thailand, 1996.