Novel Circuit Breaker Modeling in 275kV Substation

Main Article Content

Hamid Radmanesh
Razieh Salimi Atani

Abstract

Ferroresonance an electrical phenomenon may cause overvoltages in the electrical power system. In this paper, an overview of available papers is provided, at rst ferroresonance is introduced and then various type of ferroresonance in a voltage transformer (VT) is simulated. Then eect of new model of circuit breaker (CB) on damping ferroresonance oscillation is examined. Finally eect of earth resistance on the stabilizing these oscillations in the case of nonlinear core loss has been studied. Core loss is modelled by third order power series in terms of voltage and includes nonlinearities in core loss. For conrmation, the simulation is done on a one phase voltage transformer rated 100VA, 275kV. The simulation results reveal that novel modeling of circuit breaker exhibits  great controlling eect on ferrores- onance overvoltages.

Article Details

How to Cite
Radmanesh, H., & Atani, R. S. (2013). Novel Circuit Breaker Modeling in 275kV Substation. ECTI Transactions on Electrical Engineering, Electronics, and Communications, 11(2), 1–7. https://doi.org/10.37936/ecti-eec.2013112.170623
Section
Electrical Power Systems

References

[1] B.A. Mork, D.L. Stuehm, "Application of non-linear dynamics and chaos to ferroresonance in distribution systems," IEEE Transactions on Power Delivery, vol. 9, iss. 2, pp. 1009-1017, Apr. 1994.

[2] J. Bethenod, "Sur le transformateur et resonance," L'Eclairae Electrique, pp. 289-296, Nov. 1907.

[3] J.W. Butler and C. Concordia, "Analysis of series capacitor application problems," AIEE Trans., vol. 56, iss. 8, pp. 975-988, Aug. 1937.[4] C. Hayashi, "Nonlinear Oscillations in Physical Systems," NY: McGraw-Hill Book Company, New York, 1964.

[5] S. Mozaffari, M. Sameti, A.C. Soudack, "Effect of initial conditions on chaotic ferroresonance in power transformers," IEE Proc., Generation, Transmission Distribution, vol. 144, iss. 5, pp. 456-460, Sep. 1997.

[6] K. A. Anbarri, R. Ramanujam, T. Keerthiga, and K. Kuppusamy, "Analysis of nonlinear phenomena in MOV connected Transformers," IEE Proc., Generation, Transmission Distribution, vol. 48, iss. 6, pp. 562-566, Nov. 2001.

[7] F.Ben Amar,and R. Dhifaoui, "Study of the periodic ferroresonance in the electrical power networks by bifurcation diagrams," Elect. Power Energy Syst., vol. 33, iss. 1, pp. 61-85, Jan. 2011.

[8] A.H.A. Bakar, N.A. Rahim,and M.K.M. Zam bri, "Analysis of lightning-caused ferroresonance in Capacitor Voltage Transformer (CVT)," Elect. Power Energy Syst., vol. 33, iss. 9, pp. 1536-1541, Nov. 2011.

[9] S. L. Varricchio, S. Gomes Jr, and R. D. Rangel, "Three winding transformer s-domain model for modal analysis of electrical networks," Elect. Power Energy Syst., vol. 33, iss. 3, pp. 420-429, Mar. 2011.

[10] J. Hongjie, Y. Xiaodan,and C. Xiaodong, "Impact of the exciter voltage limit to small signal stability region of a three-bus power system," Elect. Power Energy Syst., vol. 33, iss. 10, pp.1598-1607, Dec. 2011.

[11] K. Milicevic,and Z. Emin, "Impact of initial conditions on the initiation of ferroresonance," Elect. Power Energy Syst., vol. 31, iss. 4, pp. 146-152, May 2009.

[12] Z. Emin, B. A. T. A. Zahawi, D. W. Auckland, and Y. K. Tong, "Ferroresonance in Electromagnetic Voltage Transformers: A Study Based on Nonlinear Dynamics," IEE Proc., Generation, Transmission Distribution, vol. 144, pp. 383-387, Jul. 1997.

[13] R. G. Kavasseri, "Analysis of subharmonic oscillations in a ferroresonant circuit", Elect. Power Energy Syst, vol. 28, iss. 3, pp. 207-214, Mar. 2005.

[14] Y. Li, W. Shi,and F. Li, "Novel analytical solution to fundamental ferroresonance-part I: power frequency excitation characteristic," IEEE Trans. on Power Delivery, vol. 21, no. 2, pp. 788-793, Apr. 2006.

[15] W. Piasecki, M. Florkowski, M. Fulczyk, P.Mahonen,and W. Nowak, "Mitigating ferroresonance in voltage transformers in ungrounded MV networks," IEEE Transactions on Power Deliv-ry, vol. 22, no. 4, pp. 2362-2369, Oct. 2007.

[16] L. Lima, A. Semlyen,and R. M. Iravani, "Harmonic domain periodic steady-state modeling of power electronics apparatus: SVC and TCSC," IEEE Power Eng. Review, vol. 22, iss. 12, pp. 960-967, Jul. 2003.

[17] C. Charalambous, Z. D. Wang, M. Osborne,and P. Jarman, "Sensitivity studies on power transformer ferroresonance of a 400 kV double circuit," IEE Proc., Generation, Transmission Distribution, IET, vol. 2, no. 2, pp. 159-166, Mar. 2008.

[18] E. Barbisio, O. Bottauscio, M. Chiampi, G. Crotti,and D. Giordano, "Parameters affecting ferroresonance in LCR electric circuits," IEEE Trans. Magnetics, vol. 44, no. 6, pp. 870-873, Jun. 2008.

[19] H. Radmanesh, "Controlling chaotic ferroresonance in autotransformer connecting metal oxide surge arrester and neutral earth resistance," ECTI Trans. EEC, vol. 10, no. 1, pp. 72-80, 2012.

[20] H. Radmanesh, M. Rostami, "Effect of circuit breaker shunt resistance on chaotic ferroresonance in voltage transformer," Advances Elect. Comput Eng., vol. 10, no. 3, pp. 71-77, 2010.

[21] F. B. Ajaei, M. Sanaye-Pasand,and A. Rezaei Zare,and R. Iravani, "Analysis and suppression of the coupling capacitor voltage transformer ferroresonance phenomenon," IEEE Trans. Power Delivery, vol.24, no.4, pp. 1968-1977, Oct. 2009.

[22] P. S. Moses, ; M. A. S. Masoum, ; Toliyat, H.A., "Impacts of hysteresis and magnetic couplings on the stability domain of ferroresonance in asymmetric three-phase three-leg transformers," IEEE Trans. Energy Conversion, vol. 26, no. 2, pp. 581-592, Jun. 2011.

[23] K.-H. Tseng,and P.-Y. Cheng, "Mitigating 161 kV electromagnetic potential transformers' ferroresonance with damping reactors in a gasinsulated switchgear," IEE Proc., Generation, Transmission Distribution, IET, vol. 5, no. 4, pp. 479-488, Apr. 2011.

[24] C.A. Charalambous, Z.D. Wang, P. Jarman,and J.P. Sturgess, "Frequency domain analysis of a power transformer experiencing sustained ferroresonance," IEE Proc., Generation, Transmission Distribution, IET, vol. 5, no. 6, pp. 640-649, Jun. 2011.