The Simplified Control of Three-Phase Four-Leg Shunt Active Power Filter for Harmonics Mitigation, Load Balancing and Reactive Power Compensation
Main Article Content
Abstract
In this paper, the simplified control of three-phase four-leg shunt active power filter for harmonics mitigation, load balancing and reactive power compensation is proposed. In order to calculate the harmonics, current imbalance and reactive power, the load currents are detected and transformed to dq0 variables. By using the low-pass filter, the fundamental active power current can be separated from the d-axis current. Therefore, the commanded active power filter currents are consist of d-axis harmonic currents, q-axis and 0-axis currents. These components are regulated by the PI controller with feedforward utility voltage via the four-leg space vector inverter. Moreover, the design guidelines of space vector phase-locked loop (PLL), current controllers and DC-bus voltage controller are also presented. Validity of the proposed control schemes is confirmed by the simulation.
Article Details
This journal provides immediate open access to its content on the principle that making research freely available to the public supports a greater global exchange of knowledge.
- Creative Commons Copyright License
The journal allows readers to download and share all published articles as long as they properly cite such articles; however, they cannot change them or use them commercially. This is classified as CC BY-NC-ND for the creative commons license.
- Retention of Copyright and Publishing Rights
The journal allows the authors of the published articles to hold copyrights and publishing rights without restrictions.
References
[2] H. Fujita, and H. Akagi, "A practical approach to harmonic compensation in power systems -series connection of passive and active filters," IEEE Trans. Ind. Appl., vol. 27, no. 6, pp. 1020-1025,
Dec. 1991.
[3] S. Bhattacharya, Po-Tai Cheng, and D.M. Divan, "Hybrid solutions for improving passive filter performance in high power applications," IEEE Trans. Ind. Appl., vol. 33, no. 3, pp. 732-747, Jun. 1997.
[4] H. Akagi, Nabae Akira, and Atoh Satoshi, "Control strategy of active power filters using multiple voltage-source PWM converters," IEEE Trans. Ind. Appl., vol. IA-22, no. 3, pp. 460-465, May, 1986.
[5] L.A. Moran, J.W. Dixon, and R.R. Wallace, "A three-phase active power filter operating with fixed switching frequency for reactive power and current harmonic compensation," IEEE Trans. Ind. Electron., vol. 42, no. 4, pp. 402-408, Aug. 1995.
[6] B. Singh, K. Al-Haddad, and A. Chandra, "A review of active filters for power quality improvement," IEEE Trans. Ind. Electron., vol. 46, no. 1, pp. 960-971, Oct. 1999.
[7] M. Aredes, K. Heumann, and J. Hafner, "A three-phase four-Wire shunt active filter employing a conventional three-Leg converter", European Power Electron. J., vol. 6, no. 3-4, pp. 54-59, Dec. 1996.
[8] P. Verdelho, and G. Marques, "A neutral current electronic compensator", Proc. Industrial Electron. Conf., 1998, pp. 591-595.
[9] N. Chudoung, and S. Sangwongwanich , "A simple carrier-based PWM method for three-phase four-leg inverters considering all four pole voltages simultaneously", Proc. Power Electron. Drive Syst., 2007, pp. 1020-1027.
[10] P. Iamsamang, "Improvement of voltage quality of a self-excited induction generator using an active f ilter", M.S. Thesis, Chulalongkorn Univ., Bangkok, Thailand, 2003.