A High Sensitivity of Vital Signs Detector using Fiber Optic-based Fabry-Perot Interferometer
Main Article Content
Abstract
In this paper, a development of high sensitivity for vital sign detector based on the fiber optic-based Fabry-Perot interferometer (FFPI) has been proposed. Two interested parameters; heart rate (HR), and also blood pressure (BP) are measured as the vital sign parameters for investigating the performance of the FFPI. Particularly, the proposed sensor is exploited to detect human arterial pulse for indicating the number of interference signals (fringes). A fringe counting technique is, consequently, applied in associate with the deflection of material technique to demodulate the observed number of fringes into HR and BP. Additionally, the reflective thin film with reflectance of approximately 55% is utilized for attaching to the human wrist during the measurement. Furthermore, a digital sphygmomanometer model OMRON HEM-7130 is employed as a reference sensor. After 20 times of repeatability on the same human subject, the FFPI could indicate the systolic and diastolic BP, as well as HR, with average error of 0.94%, 1.64%, and 1.01%, respectively. Moreover, the FFPI could determine the mentioned parameters in decimal numbers, as opposed to the reference sensor. This could, thus, verified that the FFPI is a very sensitive and more precise instrument for applying to the vital sign measurement.
Article Details
This journal provides immediate open access to its content on the principle that making research freely available to the public supports a greater global exchange of knowledge.
- Creative Commons Copyright License
The journal allows readers to download and share all published articles as long as they properly cite such articles; however, they cannot change them or use them commercially. This is classified as CC BY-NC-ND for the creative commons license.
- Retention of Copyright and Publishing Rights
The journal allows the authors of the published articles to hold copyrights and publishing rights without restrictions.
References
[2] M. Volpe, G. Gallo, and G. Tocci, “Novel blood pressure targets in patients with high-normal levels and grade 1 hypertension: Room for monotherapy,” International Journal of Cardiology, Vol. 291, pp. 105-111, 2019.
[3] R. Mukkamala et al., “Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice,” IEEE Transactions on Biomedical Engineering, Vol. 62, No. 8, pp. 1879-1901, 2015.
[4] K. C. Harris et al., “Hypertension Canada's 2016 Canadian Hypertension Education Program Guidelines for Blood Pressure Measurement, Diagnosis, and Assessment of Risk of Pediatric Hypertension,” Canadian Journal of Cardiology, Vol. 32, No. 5, pp. 589-597, 2016.
[5] A. S. Meidert and B. Saugel, “Techniques for Non-Invasive Monitoring of Arterial Blood Pressure,” Frontiers in Medicine, Vol. 4, No. 231, pp. 1-6, 2018.
[6] J. E. Sharman et al., “Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization,” European Heart Journal, Vol. 38, No. 37, pp. 2805-2812, 2017.
[7] R. Wadhwani, N. Siddiqui, and B. Sharma, “Assessment of accuracy of mercury sphygmo-manometer and automated oscillometric device of blood pressure measurement in population of normal individuals,” Asian Journal of Medical Sciences, Vol. 9, No. 5, pp. 17-24, 2018.
[8] S. Pullteap, “Development of an optical fiber-based interferometer for strain measurements in non-destructive application,” Electr. Eng., Vol. 99, No. 1, pp. 379-386, 2017.
[9] Saroj Pullteap and Han Cheng Seat, “An extrinsic fiber Fabry-Perot interferometer for dynamic displacement measurement,” Photonic Sens., Vol. 5, No. 1, pp. 50-59, 2015.
[10] M. Fajkus et al., “A Non-Invasive Multichannel Hybrid Fiber-Optic Sensor System for Vital Sign Monitoring,” Sensors, Vol. 17, No. 1, p. 111, 2017.
[11] D. Jia et al., “A Fiber Bragg Grating Sensor for Radial Artery Pulse Waveform Measurement,” IEEE Transactions on Biomedical Engineering, Vol. 65, No. 4, pp. 839-846, 2018.
[12] C. Leitão et al., “Central arterial pulse waveform acquisition with a portable pen-like optical fiber sensor,” Blood Pressure Monitoring, Vol. 20, No. 1, pp. 43-46, 2015.
[13] C. S. J. Leitão et al., “Plastic Optical Fiber Sensor for Noninvasive Arterial Pulse Waveform Monitoring,” IEEE Sens. J., Vol. 15, No. 1, pp. 14-18, 2015.
[14] J. Nedoma et al., “Validation of a Novel Fiber-Optic Sensor System for Monitoring Cardio-respiratory Activities During MRI Examinations,” Advances in Electrical and Electronic Engineering, Vol. 15, No. 3, pp. 536-543, 2017.
[15] V. Budinski and D. Donlagic, “A Miniature Fabry Perot Sensor for Twist/Rotation, Strain and Temperature Measurements Based on a Four-Core Fiber”, Sensors, Vol. 19, No. 7, p. 1574, 2019.
[16] J. Zhu et al., “An optical fiber Fabry–Perot pressure sensor using corrugated diaphragm and angle polished fiber,” Optical Fiber Technology, Vol. 34, pp. 42-46, 2017.
[17] F. Yu et al., “Ultrasensitive Pressure Detection of Few-Layer MoS2,” Advanced Materials, Vol. 29, No. 4, p. 1603266, 2017.
[18] C. Leitão et al., “Optical fiber sensors for central arterial pressure monitoring,” Optical and Quantum Electronics, Vol. 48, No. 218, pp. 1-9, 2016.