Frequency Response Characteristics of Rogowski Coil with Active Integrator for Lightning Measurement
Main Article Content
Abstract
This paper presents frequency response characteristics of a Rogowski coil which is developed with an active integrator. Experiments are performed in a laboratory with a frequency function generator as a source. The frequency responses of the Rogowski coil and the integrator are recorded with both magnitude and phase in order to verify the capability in measuring lightning current waveshapes. For availability in lightning current measurement in the electrical system, the developed Rogowski coil is specifically designed as a clamp on device. The standard lightning current waveshape of the first positive impulse (10/350μs) is simulated to investigate the measuring system. It is found that the frequency bandwidth of the Rogowski coil with the integrator developed in this paper is proper in lightning current measurement.
Article Details
This journal provides immediate open access to its content on the principle that making research freely available to the public supports a greater global exchange of knowledge.
- Creative Commons Copyright License
The journal allows readers to download and share all published articles as long as they properly cite such articles; however, they cannot change them or use them commercially. This is classified as CC BY-NC-ND for the creative commons license.
- Retention of Copyright and Publishing Rights
The journal allows the authors of the published articles to hold copyrights and publishing rights without restrictions.
References
[2] T. Kawabata, Y. Naito, S. Yanagawa, D. Natsuno, K. Yamamoto, “Development of a Measurement System Using a Rogowski Coil to Observe Sprit Lightning Current Flows Inside and Outside a Wind Turbine Generator System”, 2012 International Conference on Lightning Protection (ICLP), Vienna, Austria, pp. 1-5, Sept.2012
[3] The institute of electrical installation engineering of japan, “lightning protection for electrical and electronic equipment”, , Supporting the Society of information and communication technology, pp 18-31
[4] IEC 62305-1, “Protection against lightning-Part 1 : General principles”. Edition 2.0,2010-2016.
[5] Z.S. Zhang, D.M. Xiao, Y. Li, “Rogowski air coil sensor technique for on-line partial discharge measurement of power cables”, IET Science, Measurement and Technology, 24 October 2008.
[6] B. Leelachariyakul, “Development of Active and Passive Integrator used with a Rogowski coil”, Master Thesis , KMITL-2014-EN-M-020-063, 2014.
[7] P. Yutthagowith, "Rogowski coil with a non-inverting integrator used for impulse current measurement in high-voltage tests," Electric Power System Research Journal, vol. 139, pp. 101-108, Oct. 2016.