Influence of transverse baffles on thermal enhancement characteristics
Main Article Content
Abstract
The objective of this paper is to investigate the influence of transverse baffles (TB) on Nusselt number (Nu), friction factor (f), and thermal enhancement factor (TEF) in the Reynolds number (Re) range of 6,000-24,000. In the experiments, the transverse baffles (TB) have the blockage height ratio (e/H) equal to 0.30, while keeping the baffle pitch to baffle height ratio (P/e) constant at 2. The results showed that for TB (e/H=0.30, P/e=2), the highest Nusselt number (Nu) value is 96.15 and the Reynolds number of 24,000. The transverse baffle (TB) gives the highest thermal enhancement factor (TEF) of 0.97 at a Reynolds number of 6,000.
Article Details
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Copyright @2021 Engineering Transactions
Faculty of Engineering and Technology
Mahanakorn University of Technology
References
S. Liu, M. Sakr, “A comprehensive review on passive heat transfer enhancements in pipe exchangers,” Renewable and Sustainable. Energy. Reviews, vol. 19, pp. 64-81, 2013.
W. Changcharoen, and S. Eiamsa-ard, “Numerical Investigation of Turbulent Heat Transfer in Channels with Detached Rib-Arrays,” Heat Transfer—Asian Research, vol. 40(5), pp. 431–447, 2011.
C. Maradiya, J. Vadher and R. Agarwal, “The heat transfer enhancement techniques and their Thermal Performance Factor,” Journal of Basic and Applied Sciencesfer, vol. 7, pp 1-21, June 2018.
S. Yadav, and J. L. Bhagoria., “A numerical investigation of square-sectioned transverse rib roughened solar air heater,” International Journal of Thermal Sciences, vol. 79, pp. 111-131, 2014.
P. Promvonge, S. Tamna, M. Pimsarn and C. Thianpong, “Thermal characterization in a circular tube fitted with inclined horseshoe baffles,” Appl. Therm. Eng, vol.75, pp.1147-1155, 2015.
A. Tandiroglu, “Effect of flow geometry parameters on transient heat transfer for turbulent flow in a circular tube with baffle inserts,” Int. J. Heat Mass Transf, vol.49, pp.1559-1567, 2006.
Y. Mahanand, and J. R. Senapati, “Thermal enhancement study of a transverse inverted-T shaped ribbed solar air heater,” International Communications in Heat and Mass Transfer, vol. 119, 104922, 2020.
C. Thianpong, T. Chompookham, S. Skullong and P. Promvonge, “Thermal characterization of turbulent flow in a channel with isosceles triangular ribs,” Int. Commun. Heat Mass Transf, vol.36, pp.712-717, 2009.
D.S. Rawat, and A.R. Jaurker, “Enhancement of heat transfer using artificial roughness in solar air heater,” Int. J. Eng. Sci. Invent, vol.3, pp.50-63, 2014.
D.J. Kukulka and R. Smith, “Enhancement heat transfer surface development for exterior tube surfaces,” Chem. Eng. Trans, vol.32, pp.511-516, 2013.
W. Yang, S. Xue, Y. He, and W. Li, “Experimental study on the heat transfer characteristics of high blockage ribs channel,” Experimental Thermal and Fluid Science, vol. 83, pp. 248– 259, 2017.
A. Vyas, B. Mishra, and A. Srivastava, “Investigation of the effect of blockage ratio on flow and heat transfer in the wake region of a cylinder embedded in a channel using whole field dynamic measurements,” International Journal of Thermal Sciences., vol. 153, pp. 106322, 2020.
J. S. Park, Y. H. Jo, and J. S. Kwak, “Heat transfer in a rectangular duct with perforated blockages and dimpled side walls,” International Journal of Heat and Mass Transfer, vol. 97, pp. 224-231, 2020.
M. Ansari, and M. Bazargan, “Optimization of Flat Plate Solar Air Heaters with Ribbed Surfaces,” International Journal of Thermal Sciences, vol. 136, pp 356-363, 2018.
K. Toriyama S. Tada K. Ichimiya S. Funatani and Y. Tomita “A new method of temperature measurement using thermochromic liquid crystals (extension of measurable range based on spectral intensity in the narrow-band wavelength),” International Journal of Heat and Mass Transfer, vol.92, pp.483-489, 2016.
J.C. Han, L.R. Glicksman, and W.M. Rohsenow, “Heat transfer and friction for rib roughened surfaces,” International Journal of Heat and Mass Transfer, vol.21, pp.1143-1156, 1978.
B.N. Prasad, and J.S. Saini, “Effect of artificial roughness on heat transfer and friction factor in a solar air heater,” Solar Energy, vol.41(6), pp. 555-560, 1988.
Varun, R.P. Saini, and S.K. Singal, “A review on roughness geometry used in solar air heaters,” Solar Energy, vol.81(11), pp.1340-1350, 2007.
T. Alam, R.P. Saini, and J.S. Saini, “Experiment investigation on heat transfer enhancement due to V-shaped perforated blocks in a rectangular duct of solar air heater,” Energy Conversion and Management, vol.81, pp.374-383, May 2014.
A. Kumar, and A. Layek, “Thermo-hydraulic performance of solar air heater having twisted rib over absorber plate,” International Journal of Thermal Sciences, vol.133, pp.181-195, 2018.
K.R. Aharwal, B.K. Gandhi, and J.S. Saini, “Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater,” Renewable Energy, vol. 33, pp. 585-596, 2008.
M.M.K. Bhuiya, M.S.U. Chowdhury, M. Shahabuddin, M. Saha, and L.A. Memon, “Thermal characteristics in a heat exchanger tube fitted with triple twisted tape inserts,” International Communications in Heat and Mass Transfer, vol.48, pp.124-132, 2013.