Finite Element Investigation of Angle Ring Confinement for Clustered Large-size Stud Shear Connector in Full-Depth Precast Concrete Bridge Deck Panel
Main Article Content
Abstract
Full-Depth Precast Concrete (FDPC) bridge deck panel system has been used widely for highway construction due to rapid construction and replacement process as well as the cost effective. This system was used with a cluster of large size headed-stud shear connectors (31.8 mm diameter) for transferring composite actions between concrete decks and steel girders. For more effectiveness in composite actions and cracks controlling around the clustered stud, the angle steel ring confinement around the shear pocket was developed and tested by push-off. The Finite Element Analysis (FEA) was introduced in this study for investigating and comparing the tested results in terms of loads, displacements, and failure stages. The FE model with angle ring confinement showed better shear resistance and higher stiffness up to 5.7% than that without the confinement. The FEA study involved two main factors: (1) Non-linear concrete material models: Concrete Damage (CD) and Drucker Prager (DP); and (2) Aspects of angle confinement including thickness of angles and sizes of hook bars. The results showed comparable stiffness and load resistance in both concrete models. However, CD models could better identify initial cracks, but DP models predicted well for maximum shear resistance and critical failure point. The suitable aspects of the angle ring confinement were suggested either 5 mm thick angles with DB12 hook bars or 10 mm thick angles with DB25 hook bars.