Flexural toughening of hooked-end steel fibers reinforced mortars
Main Article Content
Abstract
In this paper it was investigated the effect of hooked-end steel fiber at varying fiber content on the flexural behavior of fiber reinforced cement mortars (FRCM) using three-point bending tests. In particular, three weight fractions (0.3%, 0.5% and 0.7%) and two cement matrices (M10 and M15), for total 8 batches, were investigated. The results evidenced that the mechanical bending behavior of the FRCM varies significantly at varying fiber content and cement plaster matrix. Compared to the unreinforced mortars, the maximum flexural strengths of the FRCM samples increases up to 146% and 134% for the M10 and M15 based composite batches with 0.7 wt.% of steel fibers, respectively. All composite mortars exhibited a toughness index (TI) in the range 10-45, indicating a suitable strengthening and toughening effect supplied by the hooked -end fiber addition. Best TI value equal to 44 was experienced for M10-D7 batch characterized by 0.7 wt.% of hooked-end steel fibers and an M10 cement matrix. Furthermore, unlike unreinforced concrete where brittle and unexpected failure occurs dominated by a sudden and catastrophic propagation of tensile cracks, the FRCM samples exhibited a ductile behavior with a marked residual post-crack resistance even for composites mortars with low metal fiber content.