Biomechanical Study of Scepter Locking Plate System for Greater Tuberosity Humerus Fracture Fixation: A Finite Element Analysis

Main Article Content

Ratthapoom Watcharopas
Wiroj Limtrakarn

Abstract

This paper presents a biomochanical study of a proximal humerus locking plate (PHILOS) and a new locking plate for the humerous fracture treatment of greater tuberosity. A new locking plate is designed in scepter shape. Fiber wire is applied to reduce a number of screw. The finite element analysis was applied. Finite element model consists of cortical and cancellous bones of humerus, supraspinatus and infraspinatus tendons, both locking plates, screws, and fiber wires. The finite element model was conducted to evaluate the biomechanical behavior of the scepter locking plate-screw-wire fixation under natural loading conditions i.e. contraction force 200 N and 100 N on supraspinatus and infraspinatus tendons, respectively, and compared to the and PHILOS plate-screw-wire fixation. The maximum von mises stress and factor of safety on PHILOS plate and scepter locking plate are 334.1 N/mm2, 2.07 and 590.9 N/mm2, 1.17, respectively. The maximum strain of two surface and maximum displacement of fracture gap of PHILOS system model and scepter locking plate system model were 0.3937%, 0.54 mm and 0.492%, 0.49 mm, respectively. The proper strain and maximum displacement of fracture gap that can promote primary heeling is less than 2% and 1 mm, respectively. The results indicate that the scepter locking plate-scew-wire fixation exhibits comparable or non-inferior mechanical properties and no effect to heeling process, including stiffness and stress concentration, but smaller and shorter than the PHILOS plate-scew-wire fixation. The scepter locking plate also obtains smaller incisions and reduces soft tissue tramus as well as lower weight and cost. These findings suggest that the scepter locking plate design including scew-wire fixation is more specifically tailored to the humerous fracture treatment of greater tuberosity than PHILOS plate-scew-wire fixation and may offer advantages in surgical technique and outcome. This scepter locking plate system could be a viable alternative for the fracture treatment of greater tuberosity.

Article Details

How to Cite
Watcharopas, R., Limtrakarn, W. ., & Kansue, P. (2026). Biomechanical Study of Scepter Locking Plate System for Greater Tuberosity Humerus Fracture Fixation: A Finite Element Analysis. Applied Science and Engineering Progress. Retrieved from https://ph02.tci-thaijo.org/index.php/ijast/article/view/255367
Section
Review Articles