A Analysis of Turbine Shaft Vibration under Dynamic Load
Main Article Content
Abstract
This study examines how imbalance and bearing wear impact vibration in a rotating shaft system at a southern Iraqi natural gas liquefaction plant. The study examines coupling imbalance and erosion in a two-stage gas turbine supported by four journal bearings. The ADRE-408 Bentley Nevada system used proximity probe sensors to measure X and Y axis vibrations. Experimental results show that adding 10g and 20g masses at 0° and 30° counterclockwise significantly increases vibration amplitude, from 22.46 µm at 113.75 Hz to 24.35 µm at 117.5 Hz. Replace worn couplings and bearings to stabilize the system, reduce vibration, and shift crucial frequencies. These findings show that mass loss and bearing wear degrade rotating machinery dynamics. Regular diagnostic monitoring is essential to prevent mechanical breakdowns and maintain rotational system performance and stability.