Comparison of Extraction Techniques on Dried Lavender Flowers Using Gas Chromatography-Mass Spectrometry
Main Article Content
Abstract
This study compared three extraction techniques, including steam distillation (SD), simultaneous distillation–extraction (SDE), and solvent assisted flavor evaporation (SAFE), to investigate their effects on the volatile composition of dried Lavandula angustifolia flowers. Volatiles were analyzed using gas chromatography–mass spectrometry (GC-MS), while four key odorants (linalool, linalyl acetate, lavandulol, and lavandulyl acetate) were quantified by gas chromatography–flame ionization detection (GC-FID). A total of 30 compounds were identified using spectral and retention index matches to an in-house library and NIST 17. Two-way ANOVA revealed significant differences among extraction methods (p < 0.05). SD yielded the highest concentrations of linalool and linalyl acetate, consistent with ISO 3515:2002 specifications, while SAFE produced the lowest amounts. However, SAFE provided the most diverse profile, capturing more thermally labile and minor compounds than SD or SDE. These results highlight a trade-off: SD maximizes yields of ISO-defined volatiles, whereas SAFE better reflects aroma authenticity, offering complementary insights for lavender quality assessment from a sensomics perspective.