The Influence of Fiber Orientation on the Energy Absorption Performance of Hybrid Double Hat Structures under Bending Impact
Main Article Content
Abstract
This study investigated the energy absorption performance of hybrid composite structures combining carbon fiber reinforced polymer (CFRP) and glass fiber reinforced polymer (GFRP). The structures were fabricated in a double hat configuration and tested under bending impact loading. Sixteen fiber-orientation configurations based on two stacking sequences: [0/90] and [45/-45]. All specimens were produced using a vacuum forming process and tested using a vertical impact testing machine at an impact velocity of 5.42 m/s. A finite element model was developed to simulate the damage behavior of the double hat structures under impact. The results showed that the carbon fiber-only configuration with the orientation CC[45/-45]4 achieved the highest specific energy absorption of 0.364 kJ./kg. The hybrid configuration combining carbon and glass fibers also demonstrated comparable performance. Specifically, the CG[45/-45]4 structure achieved a specific energy absorption of 0.261 kJ/kg. The primary advantage of the hybrid design is the reduction in overall material cost, given the high price of carbon fiber. At the same time, the hybrid material maintains energy absorption performance comparable to that of the full carbon fiber composite. reduction. Therefore, hybrid composites represent a cost-effective alternative without compromising mechanical performance.