Submerged Membrane Bioreactor with Chitosan Bead Addition and Optimization of Operational Parameters
Main Article Content
Abstract
Abstract
In the present study the influence of suction flux, chitosan bead addition and aeration intensity on fouling was investigated using 23 factorial designs. Maximum and minimum values for suction flux (4–8 L/m2.h), chitosan bead addition (0.25–0.5 g/g MLSS) and aeration intensity (0.3–0.6 m3/m2.h) were adopted as the base of membrane bioreactor operation for synthetic wastewater treatment. Concerning the fouling ability of the three factors, suction flux was observed to have the largest effect on resistance increase followed by aeration intensity and chitosan bead addition. The best recommendation of the system operation was performed at low suction flux with high aeration intensity and high chitosan bead addition.
Article Details
The published articles are copyright of the Engineering Journal of Research and Development, The Engineering Institute of Thailand Under H.M. The King's Patronage (EIT).