การศึกษาประสิทธิผลของเครื่องอุ่นอากาศแบบท่อความร้อนหน้าตัดแบนชนิดสั่นวงรอบ
Main Article Content
Abstract
This experimental research has been carried out to investigate the effectiveness of air pre-heater with closed loop oscillating flat heat pipe (CLOFHP). The lengths of both the evaporator and condenser sections of the air pre-heater were 0.30 m, and adiabatic section had a length of 0.10 m. The CLOFHP made from a copper tube with a circular cross section, which bent and pressed for a flat thickness of 2 mm. Distilled water was used as the working fluid with a fill ratio of 50% of the total internal volume. A test rig was constructed for a test of the effectiveness of an air pre-heater. The temperature of fresh-air inlet the condenser section was approximately 30oC while the hot-air temperature flow into the evaporator section was varied in the range of 90–150oC. Both of the hot and fresh air velocities across the air pre-heater were varied in the range of 0.5-2.0 m/s. The results found that, when the hot-air inlet-temperature increased with a lower velocity, the effectiveness of the air pre-heater also increased. Moreover, the minimum effectiveness occurs at the hot and fresh air velocity was equal.
Article Details
The published articles are copyright of the Engineering Journal of Research and Development, The Engineering Institute of Thailand Under H.M. The King's Patronage (EIT).