Abstract

The peak surface temperature of ceiling surface of a house in the hot and humid climate reaches 36-38 °C in the afternoon that causes uncomfortable condition and leads to high cooling energy consumption. Therefore, driving hot air off the attic by ventilation is a technique to reduce air and surface temperatures simultaneously. Using computational models in ANSYS Fluent and the average measured surface and air temperatures as the boundary conditions, this study investigated airflow and temperature reduction by forced convection produced by small exhaust fans and winglets. The three dimensional simulation model comprised of a vertical air gap connecting with a horizontal 10-cm air gap with dimensions of 3.0 m x 3.8 m x 0.13 m above the ceiling. Two fans of 680 m3/hour (100 Watts) placed at the two outlets at the soffit induced cool air of 25 °C from the ground floor flowing through the air channels and conveying heat out of the house. The validation of the simulation results was conducted by comparing with the previous experiments on horizontal air duct with hot surface facing down. The simulation results of exhaust fans turning on for 10 seconds showed the average air velocity in the horizontal channel increased to 1.0-1.5 m/s and air temperature reduced by 6.5-11.7 °C from 38.0 °C. The Installation of 2 rows of rectangular winglets with half air gap height, length of 30 cm and angle of attack of 45° increased the Nusselt number by 3 times of air gap without winglets. The vortices rotation enhanced convection heat transfer process near the winglets and decreased air temperature near surfaces by 2°C for 40 cm downstream from the rear tip of the winglets. Therefore, adopting of the system that consists of air gap formed by ceiling plates, the exhaust fans at the house soffits and two rows of winglets are preferable to reduce the effect of heat transfer in the attic.

Downloads

Download data is not yet available.

References

Al-Obaidi, K. M., Mazra, I. & Rahman, A. M. A. (2014). A review of the potential of attic ventilation and active turbine ventilators in tropical Malaysia. Sustainable Cities and Society, 52, 232-240.

Azevedo, L. F. A. & Sparrow, E. M. (1985). Natural convection in opened-ended inclined channels. Journal of Heat Transfer, 107, 893-901.

Bekele, A., Mishra, M. & Dutta, S. (2011). Effects of delta- shaped obstacles on the thermal performance of solar air heater. Advanced Mechanical Engineering, 1-10.

Bunnag, T., Khedari, J., Hirunlabh, J. & Zeghmati, B. (2004). Experimental investigation of free convection in an open-ended inclined rectangular channel heated from the top. Ambient Energy, 25, 151-162.

Han, J. C. & Zhang, Y. M. (1991). High performance heat transfer ducts with parallel broken and V-shape broken ribs. International Journal of Heat and Mass Transfer, 35, 513-29.

Hirunlabh, J., Wachirapuwadon, S., Pratinthong, N. & Khedari, J. (2001). New configuration of a solar collector maximizing natural ventilation. Building and Environment, 36, 383-391.

Hwang J. J. & Liou, T. M. (1995). Heat transfer in a rectangular channel with perforated turbulence promoters using holographic interferometry measurement. International Journal of Heat and Mass Transfer, 38, 3197-207.

Moon, S. W. & Lau, S. C. (2003). Heat transfer between blockages with holes in a rectangular channel. J. Heat Transfer, 125(4) 587-593.

Ong, K. S. (2011). Temperature reduction in attic and ceiling via insulation of several passive roof design. Energy conversion and Management, 52, 2405-2411.

Parker, D. S. (2005). Literature review of the impact and need for attic ventilation in Florida homes. Florida, USA: Florida Solar Energy Center.

Petchdee, P. & Chungloo, S. (2013). Improvement of louvers and openings of factory building to remove heat through natural wind. Journal of Architectural/Planning Research and Studies, 10(2), 31-44.

Sara, O. N., Pekdemir, T., Yapici, S. & Yilmaz, M. (2001). Heat- transfer enhancement in a channel flow with perforated rectangular blocks. Heat and Fluid Flow, 22, 509-18.

Thianpong, C., Yongsiri, K., Nanan, K. & Eiamsa-ard, S. (2012). Thermal performance evaluation of heat exchangers fitted with twisted-ring turbulators. International Communications in Heat and Mass Transfer, 39, 861-68.

Zhou, G. & Ye, Q. (2012). Experimental investigations of thermal and flow characteristics of curved trapezoidal winglet type vortex generators. Applied Thermal Engineering, 37, 241-48.

Ziskind, G., Dubovsky, V. & Letan, R. (2002). Ventilation by natural convection of a one-story building. Energy and Buildings, 34, 91-102.

Downloads

Published

2014-12-29

How to Cite

Aimkamon, P., Nontakaew, U., & Sudprasert, S. (2014). Numerical Study of Reduction of Ceiling Heat Load by Forced Convection. International Journal of Building, Urban, Interior and Landscape Technology (BUILT), 4, 25–36. Retrieved from https://ph02.tci-thaijo.org/index.php/BUILT/article/view/170255