Image Quality Comparison and Clinical Evaluation for U-Arm Digital Radiography

Authors

  • Kitti Koonsanit National Science and Technology Development Agency, Pathum Thani 12120, Thailand
  • Saowapak Thongvigitmanee National Science and Technology Development Agency, Pathum Thani 12120, Thailand
  • Walita Narkbuakaew National Science and Technology Development Agency, Pathum Thani 12120, Thailand
  • Sorapong Aootaphao National Science and Technology Development Agency, Pathum Thani 12120, Thailand
  • Natthawan Suwannajit National Science and Technology Development Agency, Pathum Thani 12120, Thailand
  • Thossapol Chunkiri National Science and Technology Development Agency, Pathum Thani 12120, Thailand
  • Jaturong Jitsaard National Science and Technology Development Agency, Pathum Thani 12120, Thailand
  • Pairash Thajchayapong National Science and Technology Development Agency, Pathum Thani 12120, Thailand
  • Utairat Chaumrattanakul Department of Radiology, Faculty of Medicine, Thammasat University, Pathum Thani 12120, Thailand

Keywords:

Digital radiography, X-Ray, Medical imaging, Chest imaging, Clinical evaluation

Abstract

The aim of this research was to assess the image quality and clinical evaluation for the proposed U-arm digital radiography system. The development of the proposed U-arm digital radiography system includes both hardware and software parts. The quality of images from the proposed system was tested and compared with three different machines using a radiographic image quality phantom and a radiographic chest phantom. Then two specialized radiologists conducted clinical evaluation based on visual grading analysis. The experimental results show that the X-ray image from the proposed machine yielded the high-contrast resolution of 3.1 line pairs per mm, while others were in the range of 2.8-3.4 line pairs per mm. The low contrast detectability and grayscale level discrimination are comparable to other machines. Two specialized radiologists evaluated the image quality of 42 volunteers and the overall satisfaction was about 82%. The image quality of the proposed digital radiography machine using the phantom is comparable to other digital radiography machines. Moreover, the evaluation from two radiologists confirms its capability for screening and diagnosis in chest imaging.

Downloads

Published

2020-09-21

How to Cite

Koonsanit, K., Thongvigitmanee, S. ., Narkbuakaew, W. ., Aootaphao, S. ., Suwannajit, N. ., Chunkiri, T. ., Jitsaard, J. ., Thajchayapong, P. ., & Chaumrattanakul, U. . (2020). Image Quality Comparison and Clinical Evaluation for U-Arm Digital Radiography. Science & Technology Asia, 25(3), 1–10. Retrieved from https://ph02.tci-thaijo.org/index.php/SciTechAsia/article/view/219524