Flexural Performance of Corroded Reinforced Concrete Beams Repaired with CFRP Sheets

Main Article Content

Arnon Wongkaew

Abstract

Corrosion of steel reinforcements in concrete is one of the main causes of early deterioration and reduction of service loads of reinforced concrete (RC) structures. This paper reports the results of an experimental program that was carried out to evaluate the effect of reinforcement corrosion on the flexural performance of RC beams, and to investigate the efficiency of externally bonded carbon fiber reinforced polymer (CFRP) sheets to repair the corrosion-damaged RC beams. Seven RC beams with the same cross section and reinforcement details were prepared, including the control beam (B0). First, tension reinforcements of six RC beams were corroded by using an accelerated impress-current process to obtain corrosion levels of 15%, 30%, and 50% of weight loss, according to Faraday’s law. Then, three beams were repaired using CFRP sheets attached to the bottom surface, leaving the other three unrepaired. All beams were subjected to the four-point bending load test. The experimental results show that the corrosion specimens demonstrated a significant deterioration on the structural performance and the integrity by decreasing in their ultimate load capacity, stiffness, and ductility. The deterioration by corrosion of tension reinforcements can be successfully overcome using CFRP sheets as the repair material. The technique can restore the beam strength to its original design strength, except specimen B50F2 having severe steel-corrosion damage of 50%. A conservative value of the ultimate bending capacity of the beams with low corrosions (15%-30%) can be predicted by using RC conventional models, as suggested in ACI 318. However, the opposite trend is obtained for the high corrosion beam (50%). Appling ACI 440.2R provision to predict the ultimate flexural capacity of corroded beams repaired with CFRP sheets shows rather fair values for low corrosions (15%-30%), but significantly overestimates the strength of the high corrosion beam (50%).

Article Details

How to Cite
[1]
A. Wongkaew, “Flexural Performance of Corroded Reinforced Concrete Beams Repaired with CFRP Sheets”, RMUTP RESEARCH JOURNAL, vol. 15, no. 2, pp. 88–102, Dec. 2021.
Section
บทความวิจัย (Research Articles)

References

P. Mangat and M. Elgarf, “Flexural Strength of concrete beams with corroding reinforcement,” ACI Struct. J., vol. 96, pp. 149-158, 1999.

Y. Ballim and J. Reid, “Reinforcement corrosion and the deflection of RC beams-an experimental critique of current test methods,” Cem. Concr. Compos. J., vol. 25, pp. 625-632, 2003.

M. Goitseone, A. Mark and M. Pilate, “Variation of steel loss and its effect on the ultimate flexural capacity of RC beams corroded and repaired under load,” Constr. Build. Mater., vol. 24, pp. 1051-1059, 2010.

X. Gu, W. Zhang and D. Shang, “Flexural Behavior of Corroded Reinforced Concrete Beams,” in Proceedings of the 12th Biennial International Conference on Engineering, Construction, and Operations in Challenging Environments, Honolulu, HI, USA, 2010.

W. Zhu, R. François, D. Coronelli and D. Cleland, “Effect of corrosion of reinforcement on the mechanical behavior of highly corroded RC beams,” Eng. Struct. J., vol. 56, pp. 544-554, 2013.

A. Torres-Acosta, M. Fabela-Gallegos, A. Munoz-Noval, D. Vazquez-Vega, T. Hernandez-Jimenez and M. Martinez-Madrid, “Influence of corrosion on the structural performance of reinforced concrete beams,” Corrosion, vol. 60, pp. 862-872, 2004.

A. Al-Saidyn and K. Al-Jabri, “Effect of damaged concrete cover on the behavior of corroded concrete beams repaired with CFRP sheets,” Compos. Struct., vol. 93, pp. 1775-1786, 2011.

R. Haddad, “Hybrid repair configurations with CFRP composites for recovering structural performance of steel-corroded beams,” Construction and Building Materials, vol. 124, pp. 508-518, 2016.

J. Rodriguez, L. Ortega and J. Casal, “Load Carrying Capacity of Concrete Structures with Corroded Reinforcement,” Constr. Build. Mater., vol. 11, pp. 239-248, 1997.

ASTM G1., “Standard Practice for Preparing, Cleaning, and Evaluating Corrosion Test Specimens,” American Society for Testing and Materials: West Conshohocken, PA, USA, 2003.

ACI Committee 318-14., “Building Code Requirements for Structural Concrete,” American Concrete Institute: Farmington Hills, MI, USA, 2014.

ACI Committee 440.2R-17., “Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures,” American Concrete Institute: Farmington Hills, MI, USA, 2017.

J. MacGregor and J. Wight, “Reinforced Concrete Mechanics and Design,” 4th ed. Boston: Pearson, 2005.