This paper presents a component model of an unbalanced three-phase distribution system and load flow analysis by forward-backward sweep methods. For instance, models of essential components include sources, transformers, distribution lines, feeder loads, and the electric vehicles (EVs) load. Significantly, the EVs load state is crucial in the future distribution system. The simulation results show that the accuracy is close to the acceptable level compared to the reference research. Moreover, a greater Evs load penetration affects the magnitude of the voltage more than a smaller one. Therefore, the load flow analysis with EVs load penetration is essential. The modeling and methods need accurate and precise improvement for future distribution system operations.

Article Details

How to Cite
Bootthanu, N. ., Boribun, B. ., Thammawongsa, N. ., & Bhumiphan, N. . (2023). Load flow analysis for unbalanced radial distribution system with the penetration of electric vehicles. Industrial Technology Journal Surin Rajabhat University, 8(2), 111–123. https://doi.org/10.14456/journalindus.2023.22
Section
Research articles

References

Adusumilii, B. S., & Kumar, B. K. (2020). Backward/forward sweep based power flow analysis of distribution systems under uncertainty using new affine arithmetic division. Paper presented at the 2020 IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT).

Bompard, E., Carpaneto, E., Chicco, G., & Napoli, R. (2000). Convergence of the backward/forward sweep method for the load-flow analysis of radial distribution systems. “International Journal of Electrical Power & Energy Systems”. 22(7) : 521-530.

Das, D., Kothari, D., & Kalam, A. (1995). “Simple and efficient method for load flow solution of radial distribution networks”. International Journal of Electrical Power & Energy Systems. 17(5) : 335-346.

Grigsby, L. L. (2012). Electric power generation, transmission, and distribution. 3ed. Taylor & Francis Group, LLC.

Kersting, W. H., & Kerestes, R. J. (2023). Distribution system modeling and analysis with MATLAB and WindMil. Florida: CRC Press.

Kocar, I., & Lacroix, J.-S. (2011). Implementation of a modified augmented nodal analysis based transformer model into the backward forward sweep solver. “IEEE Transactions on Power Systems”. 27(2) : 663-670.

Kron, G. (1951). Tensorial Analysis of Integrated Transmission Systems Part I. The Six Basic Reference Frames. “Transactions of the American Institute of Electrical Engineers”. 70(2) : 1239-1248.

Mishra, S., & Das, D. (2008). Distribution system load flow methods: a review. Icfai Univ. J. Electr. Electron. Eng. I, 2.

Rana, A., Darji, J., & Pandya, M. (2014). Backward/forward sweep load flow algorithm for radial distribution system. “International journal for scientific research and development”. 2(1) : 398-400.

Shirmohammadi, D., Hong, H. W., Semlyen, A., & Luo, G. X. (1988). A compensation-based power flow method for weakly meshed distribution and transmission networks. “IEEE Transactions on Power Systems”. 3(2) : 753-762.

Tian, J., Lv, Y., Zhao, Q., Gong, Y., Li, C., Ding, H., & Yu, Y. (2022). “Electric vehicle charging load prediction considering the orderly charging”. Energy Reports. 8 : 124-134.