Installation of a turntable type meter for proper use

Main Article Content

ปัณณธร รอดกำเนิด

Abstract

Provincial Electricity Authority (PEA), in the past, used a rotary-type meter as a meter to measure electricity usage of electricity users (EGAT) in which the amount of the meter that was installed When passing through the use, there may be a possibility that the form is incorrect due to the installation of PEA standards. Such problems cause the meter to have a chance to display incorrect energy usage. Away from reality This article presents an adjustment of the angle of installation of a rotating disk type meter so that there is minimal display error. By simulating the angle of inclination in Install meter And calculate the error value in each tilt display The result of the test shows the angle of inclination that causes the meter to display incorrectly, as a guideline for inspection in order to reduce wasted units and digitally switch the measurement strategy.

Article Details

How to Cite
รอดกำเนิด ป. (2020). Installation of a turntable type meter for proper use. Industrial Technology Journal Surin Rajabhat University, 5(1), 1–7. retrieved from https://ph02.tci-thaijo.org/index.php/journalindus/article/view/241022
Section
Research articles

References

B. Cai, M. Gao, W. Zhou and Z. He. (2013). "A Design of Error Computing System for

Multifunctional Watt-Hour Meter." 2013 Third International Conference on

Instrumentation, Measurement, Computer, Communication and Control, Shenyang,

pp. 715-718.

D. Gallo, C. Landi, M. Luiso, G. Bucci and E. Fiorucci. ( 2013). "Low cost smart power metering."

IEEE International Instrumentation and Measurement Technology Conference

(I2MTC).Minneapolis, MN, 2013, pp. 763-767.

Edison Electric Institute (EEI).( 2002)."Handbook for Electricity Metering," 10th Edition, 2002,

Washington, pp. 151-162.

E. E. Lynch and M. A. Princi. (1942). "Improvement in modern meter-testing technique," in

Electrical Engineering, 61(4), pp. 218-223, April.

H. D. Stryczewska, R. Goleman, M. Pietras and T. Giżewski.( 2017)."Evaluation of the damages

in three-phase watt-hour induction meters after external high magnetic field exposition,"

International Conference on Electromagnetic Devices and Processes in

Environment Protection with Seminar Applications of Superconductors (ELMECO &

AoS), Lublin, 2017, pp. 1-4.

M. M. Saied.(1995). "On the accuracy of watt-hour meters in nonsinusoidal environment,"

IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference

Thirtieth IAS Annual Meeting, Orlando, FL, USA, pp. 2219-2225 vol.3.